Adjust the outlet regulator by turning its knob while air flows and watching the outlet gauge. On most regulators, turning the knob clockwise raises the outlet pressure. Set the outlet at or below your tool’s maximum rating, then lock the setting. The pressure switch on the compressor is a separate control, and it decides when the motor starts and stops.
Know which gauge you’re reading
Compressors have two gauges that are easy to confuse:
- The tank gauge shows the pressure stored in the tank. It is usually the higher reading.
- The outlet (regulator) gauge shows the pressure sent to your tools. This is the reading to set.
If you adjust the regulator and the tank gauge doesn’t change, that’s normal. The regulator controls the outlet, not the tank.
Before you adjust
- Check your tool’s maximum pressure in its manual. Many air tools are rated around 90 psi, but your tool may differ.
- Check the rating on your hose, couplers, and fittings. The outlet pressure must stay within the lowest rating in the path.
- Close drains and check for leaks first. A leak can make the reading seem to drop when you’re setting the pressure.
- Look for a lock on the knob. Some regulators have a lock nut or a pull-up knob.
Step-by-step: set the outlet regulator
- Connect the tool you will use, or a gauge, to the regulator’s outlet.
- If your regulator has a lock, pull the knob up or loosen the lock nut.
- Turn the knob clockwise to raise the outlet pressure, or counterclockwise to lower it. Check the arrow or label on your regulator.
- Run the tool while you watch the outlet gauge. Set the pressure at the tool’s working level, because pressure dips when a tool draws air.
- Lock the knob if your regulator has a lock.
- Recheck the gauge after a few minutes of use, because pressure can drift.
Regulator vs. pressure switch
The regulator sets the pressure going to your tools. The pressure switch controls when the compressor starts and stops, which sets the tank pressure. Many switches have a fixed gap between the cut-in pressure (where the motor starts) and the cut-out pressure (where it stops).
Adjusting or replacing the pressure switch is electrical work and a different job. If you need to change it, follow your compressor’s manual. If you’re not sure, have a technician do it. For more on what the switch does, see why an air compressor won’t go over 40 psi.
What pressure should I use?
Use the lowest outlet pressure that your tool needs, and keep it at or below the tool’s maximum rating. Higher pressure makes the compressor work harder and uses more energy. A lower outlet setting also reduces the stress on hoses and fittings.
Troubleshooting
- The outlet pressure won’t hold steady. Check for leaks, and make sure the regulator is set while air flows. A regulator that is too small for the flow can also struggle. See air compressor regulators.
- The outlet pressure keeps creeping up. A worn or dirty regulator may be the cause. Check the filter upstream, and consider replacing the regulator if it keeps drifting.
- The outlet reads zero. Check that the outlet valve is open and that the tank has pressure on its gauge.
- Tools feel weak at a higher setting. Check the hose length and size. See how long an air hose can be before pressure drops.
Safety
- Don’t adjust the pressure switch or the relief valve unless you understand the procedure. Disconnect power first, and never plug or modify the safety relief valve.
- Keep the outlet below the rating of the lowest-rated part in the path.
- Wear eye protection when you run air through a tool or a test line.
For how regulators work and how to size one, see air compressor regulators. For leaks that can affect the reading, see finding and fixing compressed air leaks.