Finding and Fixing Compressed Air Leaks

Find and fix compressed air leaks with a soap test and a pressure-decay check, and estimate what leaks cost with a simple formula you can run yourself.

On this page
  1. Why is my compressor leaking air?
  2. Signs of a leak
  3. Find the leak
  4. What pressure should I use for a leak test?
  5. How much do air leaks cost?
  6. Fix common leak points
  7. Verify the fix
  8. Safety

Compressed air leaks waste energy, reduce tool performance, and make the compressor run more than it should. Most leaks are at fittings, hose ends, couplers, and drains, and a soapy-water test finds most of them. This article covers where leaks usually are, how to find them, what pressure to test at, how to estimate what they cost, and how to fix the common leak points.

Why is my compressor leaking air?

The leak is usually in one of three places:

  • The distribution system: fittings, hoses, couplers, and tubing. This is the most common source.
  • The compressor side: the check valve, the tank drain, the safety relief valve, or an unloader.
  • The tools you use: worn tool fittings, a cracked hose, or a loose coupler at the tool.

Start with the distribution system. If the compressor runs often even when every tool is off and every outlet is closed, there is almost certainly a leak somewhere in the system.

The most common leak points are:

  • Threaded fittings that have loosened or lost their sealant
  • Quick couplers and plugs that are worn or mismatched
  • Hose ends, especially where the hose meets the fitting
  • Push-to-connect tubing that is not fully seated
  • Drain valves left slightly open or worn
  • A check valve between the pump and the tank that lets air flow back
  • A safety relief valve that seeps at normal pressure

Signs of a leak

  • The compressor cycles on and off with no tools running.
  • Tools slow down or lose power faster than they used to.
  • You hear hissing at fittings, or the compressor runs longer than normal.
  • The tank pressure drops quickly after the compressor shuts off.

Find the leak

Listen and feel

With the system pressurized and every tool off, walk the line and listen. Hissing is easiest to find at fittings. Keep your face and hands away from a pressurized leak, because high-speed air can injure skin and eyes.

Soapy-water test

Mix dish soap with water and brush it onto each joint, fitting, valve, hose end, and coupler. Bubbles mark a leak. Tape or mark each one, then fix it before you move on.

Pressure-decay test

A pressure-decay test shows how much the system leaks, even when you can’t see the leak. With everything shut off:

  1. Charge the tank to its normal cut-out pressure.
  2. Shut off the compressor and close every outlet.
  3. Note how long it takes for the gauge to drop a set amount, such as 10 psi.
  4. Repeat the test after each repair.

A longer time means less leakage. If the time doesn’t change after a repair, the leak you fixed wasn’t the main one.

Flow meters (optional)

A flow meter measures how much air the system uses over time. It helps you track consumption and see changes after repairs. A small shop doesn’t need one. If you do install one, a common location is in the main line downstream of the dryer.

What pressure should I use for a leak test?

Test at the system’s normal working pressure, which is the pressure your tools run at, or at the compressor’s cut-out pressure to test the whole system. Never test above the lowest maximum rating of any part in the system. If you want a lower test pressure, set the regulator lower first.

How much do air leaks cost?

Leaks cost energy. The compressor draws electricity to make air that escapes. To estimate the cost:

  1. Find the compressor’s motor power in kilowatts (kW) on the nameplate. Convert horsepower to kW if needed.
  2. Estimate the hours per year the compressor runs only to replace leaked air. Time its run cycles with all tools off and outlets closed.
  3. Multiply the power by the hours and by your electricity rate per kWh.

For example, a 3 kW motor running 1,000 hours a year at a rate of $0.15 per kWh works out to about $450 a year. This is an illustrative upper-end figure. A motor doesn’t draw its full rated power the whole time it runs, so use your own numbers.

Fix common leak points

  • Threaded fittings: Tighten first. If the leak continues, take the fitting apart, clean the threads, and reseal them with the sealant or tape your pipe type calls for. Leave the first thread bare.
  • Quick couplers and plugs: Replace worn or cracked parts. Make sure the style matches. See air coupler types.
  • Hose ends: Cut out a damaged section and re-fit the end, or replace the hose. Don’t rely on a clamp over a split.
  • Push-to-connect tubing: Cut the tube square again and push it fully into the fitting until it bottoms out.
  • Drain valves: Close them fully. Replace any that seep.
  • Check valve: If pressure drops quickly after shutdown, the check valve may be leaking back toward the pump. Have a service technician check it.
  • Relief valve: Don’t tamper with it. If it vents at normal pressure, have it replaced.

Verify the fix

Retest with the soapy-water method and the pressure-decay test. Note the times and compare them with the earlier results. Keep a simple log of run time and test results. If a repair doesn’t change the result, look for another leak point.

Safety

  • Depressurize before you tighten or replace a part.
  • Never block a pressurized leak with your hand.
  • Don’t test above the rating of the lowest-rated part.
  • Wear eye and hearing protection while testing.

For how to isolate a section of the line while you work on it, see shutoff valves and drop legs. For moisture that can enter through a poorly sealed system, see compressed dry air. For the cost of leaks in context, see disadvantages of compressed air.

The complete guide to shop air systems

How to Set Up Air Compressor Lines in Your Shop