Compressor Basics

Air Receiver Tanks: How Compressor Pressure Vessels Work

Learn what a compressor's air receiver tank does, how it's built, and why its nameplate, relief valve and drain matter for safe, steady compressed air.

On this page
  1. What an air receiver tank does
  2. Parts of a receiver tank
  3. Vertical or horizontal
  4. Materials
  5. What “pressure vessel” means
  6. Can you add air to a tank that’s already pressurized?
  7. Draining and moisture
  8. Inspection, corrosion, and replacement
  9. Safety
  10. Tank size and your compressor

An air receiver tank is the steel tank that holds compressed air between the pump and your tools. It does more than store air. It smooths out pressure, lets moisture drop out, and reduces how often the motor starts. Knowing what the tank does helps with sizing, draining, and safe use, and the markings on the tank show its limits.

What an air receiver tank does

  • Stores a reserve. Tools can draw air faster than the pump delivers it. The tank covers short bursts of demand, so the motor doesn’t have to run all the time.
  • Smooths pressure. Piston compressors deliver air in pulses. The tank evens out those pulses, which helps keep the pressure at the tool steadier.
  • Lets moisture drop out. Air cools in the tank, and water vapor condenses into liquid. The water settles at the bottom, where the drain valve can remove it.
  • Reduces motor starts. A larger reserve means fewer starts and stops for the same amount of work. Frequent starts can add wear to the motor and the pressure switch.

Parts of a receiver tank

  • Shell and heads. The shell is the cylindrical body. The ends are rounded or dished, which spreads internal stress more evenly than flat ends would.
  • Nameplate. Lists the maximum allowable working pressure and the tank’s volume, and may carry certification marks. Read it before anything else.
  • Safety relief valve. A spring-loaded valve that opens if the pressure rises above a safe level. It is a backup, so don’t adjust or block it.
  • Pressure gauge. Shows the pressure inside the tank.
  • Drain valve. Sits at the lowest point of the tank and removes condensed water.
  • Ports. Threaded fittings for the inlet from the pump, the outlet to the regulator, and any accessories.

Vertical or horizontal

Receiver tanks come in vertical and horizontal orientations. Vertical tanks take up less floor space. Horizontal tanks sit lower and can be easier to fit under a bench. Either way, the drain sits at the lowest point of the tank, so check that you can reach it.

Materials

Most receiver tanks are made of carbon steel, which is common and strong. Stainless steel resists corrosion better but costs more. Some small portable tanks use aluminum, which is lighter. Check the nameplate and the manufacturer’s documentation for the material and the pressure rating. Don’t assume a tank can safely handle more pressure than it is rated for.

What “pressure vessel” means

A pressure vessel is a closed container that holds gas or liquid at a pressure significantly different from the surrounding air. The ASME pressure vessel code, for example, applies to vessels with internal pressure above 15 psi. Most compressor tanks operate well above that level, which is why many carry code markings and manufacturer documentation.

Pressure vessel steel is the plate material the tank is built from. Code-built tanks use steel that is specified for pressure service. A common example is ASTM A516 Grade 70, a carbon steel plate. If you need the material for a specific tank, look for it in the documentation.

Can you add air to a tank that’s already pressurized?

Yes. A compressor can refill a tank that already holds air. The pump only adds air while its output pressure is higher than the tank pressure, and the check valve keeps stored air from flowing back toward the pump. You don’t need to empty the tank first.

Draining is a separate task. It removes water, and it’s worth doing on a regular schedule regardless of how much air is stored.

Draining and moisture

Compressed air carries water vapor, and that water condenses as the air cools in the tank. Drain the tank when it’s empty or nearly empty and the unit is off and unplugged, following the manual. Keep your face and body out of the path of the valve as it opens.

Water left in the tank can promote rust on the inside of the shell, which weakens the tank over time.

Inspection, corrosion, and replacement

Look over the tank regularly for rust, bulges, dents near the welds, and leaks. Check the nameplate for a date or service life if one is given. Tanks have a limited life. A badly corroded tank should be replaced or inspected by a qualified person, not patched.

Don’t weld, drill, or otherwise modify a pressure tank.

Safety

Keep the relief valve working, and never block or adjust it. Don’t run the compressor above the tank’s rated pressure. Relieve the pressure before working on the tank or its fittings. Compressed air can cause serious injury, and the OSHA guidance on compressed air covers the workplace rules that apply.

Tank size and your compressor

A bigger tank gives you more reserve and fewer starts, but the compressor still has to refill it. Match the tank size to your tools and to the compressor’s output. Air compressor types and sizes compares common tank sizes. Duty cycle explained covers how long the motor can run, and cut-in and cut-out pressure explains when the motor starts again.

For the full cycle the tank sits in, see how an air compressor works. The check valve between the pump and the tank keeps stored air from flowing back to the pump.