To size a compressor for a plasma cutter, match it to the cutter’s listed air flow (CFM) and inlet pressure, then add margin. Many handheld air plasma cutters list an inlet pressure somewhere around 80 to 100 PSI and an airflow in the mid single digits of CFM, but figures vary by model and amperage. Your cutter’s manual is the reliable source. A modest tank can handle occasional short cuts. Heavier or continuous cutting needs a larger tank, more airflow and clean, dry air.
Start With Your Cutter’s Specs
Plasma cutters need two figures from the manual:
- Air flow (CFM) at the cutter’s rated inlet pressure
- Inlet pressure, which the regulator at the cutter should be set to
Higher-amperage cutters generally use more air, so the same compressor may suit a small cutter and struggle with a larger one. Some portable plasma cutters have a built-in compressor. Check its output against the cutter’s requirement in the same way you would check a separate unit.
Add Margin
The compressor should deliver more air than the cutter needs, so pressure holds steady during a long cut. Planning guides often suggest about 1.5 times the cutter’s airflow. Heavy-production and automated cutting users sometimes go higher, because they run for long periods without a break.
Tank Size and Duty Cycle
A modest tank can handle occasional short cuts. A very small tank with limited airflow can starve the torch and cause uneven cuts. Heavy or continuous cutting calls for a larger tank and a pump rated for continuous duty, which keeps the motor from overheating. Shop-scale guides often suggest a tank of 60 gallons or more for frequent use, though the right size depends on your cutter and your cut length.
Clean, Dry Air
Moisture and oil shorten consumable life and reduce cut quality. Water in the air can wear out electrodes and nozzles quickly, and it makes cuts less consistent.
- Water separator at the compressor outlet
- Coalescing filter near the cutter to remove oil and fine water droplets
- Dryer where humidity is high or the work is sensitive
- Oil-free compressor where practical, so oil does not reach the torch
- Regular drainage of the tank and filter bowls
For how these parts work together, see how air tools work.
Airline and Fittings
Keep the airline as short as practical and use a diameter large enough for the run. Long, narrow lines cause pressure drop at the cutter. Limit the number of fittings, since each one is a possible leak. For a shop setup, guides often suggest 3/8-inch airline for runs under about 75 feet and 1/2-inch for longer runs. Use the manufacturer’s recommendation for your cutter first. For fittings and hose choices, see portable air compressor attachments and accessories.
Electrical and Circuit Planning
Check whether the compressor and the cutter share a circuit, and what each draws. Compressors have a higher starting current than running current, so the circuit must handle both. Running a compressor and a cutter at the same time on an overloaded circuit can trip breakers during a cut. If you use a generator, check its rating against the compressor’s starting load and the cutter’s draw.
Plasma Cutting Safety
Plasma cutting carries several hazards, and the air supply does not change them.
- Arc light and UV. The arc is intensely bright and emits UV. Wear a welding-rated helmet with the correct shade, and cover exposed skin.
- Fumes. Cutting coated, painted, galvanized or stainless metal can release hazardous fumes. Use local exhaust or good ventilation, and wear respiratory protection where the fume load requires it.
- Electrical safety. Keep the work clamp secure, and keep equipment dry. Do not cut in standing water.
- Hot metal and sparks. Clear the area of combustibles, and keep a fire extinguisher nearby.
Quick Sizing Checklist
- Get the cutter’s airflow (CFM) and inlet pressure from the manual.
- Compare the compressor’s CFM at the same pressure.
- Add margin, often about 1.5 times the cutter’s airflow as a planning figure.
- Choose a tank for your cut length and how often you cut.
- Plan the water separator, filter and dryer.
- Check the circuit or generator for both starting and running loads.
For a related sizing guide for shop air used with blasting, see what size air compressor you need for sandblasting. For how these tools fit into metal work more broadly, see things to do with an air compressor.